Differential Pressure Transmitter
0bar~0.35bar...35bar
Accuracy: ±0.5%FS
4~20mA DC 0/1~5V DC 0~10/20mA DC
MPM4530
Used For
Power Station, Automation Industry, Petrochemical Industry, Laboratory Instruments
Leave a MessageMPM4530 high-temperature pressure transmitter is equipped with a high-temperature pressure sensing element. It is designed for high and low temperature medium in the range of -40~150℃. The whole welding structure and rigorous production process results in a pressure transmitter with stable and reliable performance which can work in a hostile environment. With its standard output signal, the MPM4530 high temp pressure transducer integrates into existing measurement and control systems, minimizing installation time and effort. It has a long lifespan, reducing maintenance and replacement costs.
The steam pressure transducer finds extensive applications in various industries such as food manufacturing, power generation, engineering, steam and heat exchange, and laboratory instruments.
Feature
• All-welded sensor body with pressure port
• Stainless steel contacting with media provides excellent resistance to corrosion
• Pressure and temperature transducer maintains good long-term stability
• Strong anti-impact and anti-shock ability to withstand harsh operating conditions
Specifications
• Range: -0.1MPa…0MPa~0.01MPa…160MPa(G) 0MPa~0.025MPa…60MPa(A)
• Over pressure: 200%FS or 150MPa(min.value is valid)
• Media: liquid or gas which is compatible with stainless steel
• Power supply: 10~30VDC, suggested 24VDC
• Output signa:l 4~20mADC 2-wire
• Load: RL≤((U-10)/0.02)(Ω)
• Accuracy: ±0.25%FS, ±0.5%FS(including non-lin., rep. and hys.)
• Thermal error: ≤±0.025%FS/℃ (@25℃ )
• Long-term stability: ≤±0.5%FS/year
Image:
MPM4530 high-temperature pressure transmitter is equipped with a high-temperature pressure sensing element. It is designed for high and low temperature medium in the range of -40~150℃. The whole welding structure and rigorous production process results in a pressure transmitter with stable and reliable performance which can work in a hostile environment. With its standard output signal, the MPM4530 high temp pressure transducer integrates into existing measurement and control systems, minimizing installation time and effort. It has a long lifespan, reducing maintenance and replacement costs.
The steam pressure transducer finds extensive applications in various industries such as food manufacturing, power generation, engineering, steam and heat exchange, and laboratory instruments.
Feature
• All-welded sensor body with pressure port
• Stainless steel contacting with media provides excellent resistance to corrosion
• Pressure and temperature transducer maintains good long-term stability
• Strong anti-impact and anti-shock ability to withstand harsh operating conditions
Specifications
• Range: -0.1MPa…0MPa~0.01MPa…160MPa(G) 0MPa~0.025MPa…60MPa(A)
• Over pressure: 200%FS or 150MPa(min.value is valid)
• Media: liquid or gas which is compatible with stainless steel
• Power supply: 10~30VDC, suggested 24VDC
• Output signa:l 4~20mADC 2-wire
• Load: RL≤((U-10)/0.02)(Ω)
• Accuracy: ±0.25%FS, ±0.5%FS(including non-lin., rep. and hys.)
• Thermal error: ≤±0.025%FS/℃ (@25℃ )
• Long-term stability: ≤±0.5%FS/year
0bar~0.35bar...35bar
Accuracy: ±0.5%FS
4~20mA DC 0/1~5V DC 0~10/20mA DC
-1bar...0mbar~100bar…1000bar
General / Flush Diaphragm
CE, RoHS, ATEX approved
DNV and ABS certifications for installation on the ship
Range:-1bar...0~0.1bar…1000bar
Accuracy: ±0.15%FS (Typ.)
RS485/HART Protocol
DNV approved for ship use
Range: 0~250mbar to 0~250bar
Accuracy:±0.25%FS, ±0.5%FS
Output: 4mA~20mA DC, 0/1V~5/10V DC, 0.5V~4.5V DC
Using shear and agitation to evenly distribute the fibers, the pulp tank in the papermaking process combines pulp and water. Following mixing, shearing, and temperature control, the processed slurry is released to feed the machinery used in the papermaking process downstream. The slurry can only enter the headbox for the subsequent step if the level is measured accurately.
more info...The marine temperature control system uses a refrigerant circulating between the condenser and evaporator to achieve cooling, heating, and dehumidification.
more info...By monitoring the sewage flow, pipeline pressure and reservoir level, the efficiency of sewage treatment plant can be improved. At the same time, it can also facilitate operation and management, and achieve energy saving and automation control.
more info...Due to the highly diffusive, flammable, and explosive characteristics of hydrogen, strict pressure monitoring by pressure transmitters is required to ensure its safety during transportation.
more info...