中文 |English |Deutsch |Pусск
TUF2000 Ultrasonic Flowmeter
TUF2000 Ultrasonic Flowmeter

Measuring principle: Travel-time-difference method;
Accuracy: linearity is better than ±0.5%;
Repeatability: better than ±0.2%;
Measurement accuracy: better than ±1%;
Measurement period: 500ms;
Flow rate range: 0m/s to 30m/s;
Measurable medium: water, sewage, sea water, chemical solution, oil, alcohol, etc.
Turbidity: ≤ 10000 ppm, and the bubble content is small;

Introduction

The TUF2000 ultrasonic flowmeter adopts the advanced low-power single-chip technology, and selects the latest and most advanced integrated circuit and microprocessor produced by the famous semiconductor component manufacturers in the world. It can measure the fluid as water, sea water, or the uniform liquid such as oil and slurry. Either conductive or non-conductive, corrosive or non-corrosive liquid can be measured. It supports variety of mounting methods, such as insertion-type and clamp-on type.

          

Specification

Measuring principle: Travel-time-difference method;

Accuracy: linearity is better than ±0.5%;

Repeatability: better than ±0.2%;

Measurement accuracy: better than ±1%;

Measurement period: 500ms;

Flow rate range: 0m/s to 30m/s;

Measurable medium: water, sewage, sea water, chemical solution, oil, alcohol, etc.

Turbidity: ≤ 10000 ppm, and the bubble content is small;

Pipe type: steel, cast iron, cement, hard plastic, fiberglass, PVC, etc.

Pipe diameter range: different diameters from DN32mm to DN1500mm;

Straight pipe section: upstream ≥10D, downstream ≥5D, ≥30D from the pump outlet;

Fluid temperature: standard probe: -30° C~90° C;

High temperature probe: -30° C~160° C;

Protection level: sensor up to IP68, converter IP65;

Language: Chinese/English switchable;

Working power supply: 100V~ 40V AC, 8V~36V DC;

Output signal: 4mA~20mA DC or 0mA~20mA DC, etc.

Frequency signal: 1Hz~9999Hz optional, OCT output;

Alarm signal: dual OCT output, 20 sources optional;

Data interface: isolated RS485 serial interface, support MODBUS protocol;

Converter Types (Optional)

(TUF2000-SW)                   (TUF2000-SS)                       (TUF2000-SD)

Size (mm): 154×202×75 152×76(cutout required) 325×325×165

Ordering Guide

TUF2000

Ultrasonic Flowmeter

 

 

Code

Flowmeter Type

SW

wall-mounted

SS

Panel-mounted

SD

Explosion-proof

 

 

Code

Sensor Type

B1

TS-2, standard small size, magnetic, DN32~DN65,-30℃~90℃

B2

TM-1, standard medium size, magnetic, DN80~DN400,-30℃~90℃

B3

TL-1,standard large size, magnetic, DN450~DN1500,-30℃~90℃

B4

HTS-1 high-temp small size, DN32~DN65,-40℃~160℃

B5

HTM-1 high-temp medium size, DN80~DN400,-40℃~160℃

B6

HTL-1 high-temp large size, DN450~DN1000,-40℃~160℃

C1

TC-1 standard insertion-type, DN80~DN1200,-40℃~160℃

C2

TLC-2 extended insertion-type, DN80~DN1800,-40℃~160℃

 

 

NominalDiameter (mm)

XXX [ represent actual diameter, for examples, DN50~050; DN100~100]

 

 

Code

Pipeline Material

0

Carbon Steel

1

Stainless Steel (not including 316/316L)

2

Cast Iron

3

Glass Steel

4

PVC

5

Cement

6

Others

 

 

Pressure

MPa(default≦1.6MPa)

 

 

 

 

Code

Output signal

E

4mA~20mA DC(standard)

F

Frequency (upper and lower limit and range required)

R

Relay Output(Switch contact signal)

R2

RS232(Please note baud rate and communication check bit)

R8

RS485 output, standard Modbus protocol(standard)

 

 

Code

Supply

V1

DC24V(without cable)

V2

AC220V(with cable )

 

 

Sensor to Convertor distance

m(10 meter cables, 5meter per cable; special cable length requirement available, but longer than 100m is not suggested.)

 

 

    TUF2000 SW B1 050 0 1.6 ER8 V1 10 Whole Spec.


Ordering Notes

1. Measuring medium:_________________ . .

2. Working Pressure: ____ MPa and Temperature: ____ ° C.

3. Flow range: ______ Mini flow: ______ Normal Flow: ______ Max. flow:

4. Norminal diameter: ______ (mm).

5. Mounting type: ______.

6. Output type: ______.

7. Supply power:______ V.


Related Products