MPM280 Assembled/Welded Piezoresistive Pressure Sensor
MPM280 Assembled/Welded Piezoresistive Pressure Sensor

·Pressure range 0kPa~20kPa…70MPa;
·Gauge, absolute and sealed gauge type pressure sensor;
·Constant current/ Constant Voltages power supply;
·Isolated construction to measure various fluid media;
·Φ19mm OEM pressure element
·316L stainless steel material
·Tantalum diaphragm or titanium construction for option
·Different male thread connection optional

Features

·Pressure range 0kPa~20kPa…70MPa;

·Gauge, absolute and sealed gauge type pressure sensor;

·Constant current / Constant Voltages power supply;

·Isolated construction to measure various fluid media

·Φ19mm OEM pressure element

·316L stainless steel material

·Tantalum diaphragm or titanium construction for option

·Different male thread connection optional


Application

·Industrial process control                  

·Level measurement                              

·Gas, liquid pressure measurement

·Pressure meter                                

·Pressure calibrator                                

·Liquid pressure system and switch

·Refrigeration equipment and air conditioner                                                    

·Aviation and navigation inspection


Introduction

Assembled MPM280 Piezoresistive Pressure Sensor

Put general MPM280 pressure sensor into the housing with standard or specialized thread; use face type seal or waterline seal; with flexible construction and strict inspecting and screening; the assembled MPM280 pressure sensor has similar application with general type pressure sensor, it can be used for mounting and production of different pressure instruments;


Welded MPM280 Piezoresistive Pressure Sensor

Put general MPM280 pressure sensor into the housing with standard or specialized thread; and weld sensor with housing together, no O-ring for sealing. The whole product has flexible construction, it has wider application fields than general pressure sensor, and can be used for mounting and production of different pressure instruments;


Electric Performance

Power supply: ≤2.0mADC;≤10V DC

Electric connection: φ0.5mm Kovar pin or 100mm silicon rubber flexible wires

Common mode voltage output: 50% of input (typ.)

Input impedance: 3kΩ~8kΩ

Output impedance: 3.5kΩ~6kΩ

Response (10%~90%): <1ms

Insulation resistor: 100MΩ, 100VDC

Overpressure: 1.5 times FS


Construction Performance

Diaphragm: stainless steel 316L Titanium TA1 (MPM280Ti) Tantalum Ta (MPM280TH, MPM280TS)Hastelloy C(MPM280HH)

Housing: stainless steel 316L Titanium TC4 (MPM280Ti) Hastelloy C (MPM280TH,MPM280HH)

Pressure leading tube: stainless steel 316L 

Pin: Kovar

O-ring: Viton

Net weight: ~23g(general type, MPM280TH and MPM280TS)

~50g(flush diaphragm)

~125g(assembled type)

~13.5g (MPM 280Ti)


Environment Condition

Shock: no change at 10gRMS, (20~2000)Hz

Impact: 100g, 11ms

Media compatibility: the gas or liquid which is compatible with construction material and Viton


Basic Condition

Media temperature: (25±1)℃

Environment temperature: (25±1)℃

Shock: 0.1g (1m/s2) Max

Humidity: (50%±10%)RH

Local air pressure: (86~106)kPa

Power supply: (1.5±0.0015)mADC


Specification

Item*

Min.

Typ.

Max.

Units

Linearity

±0.15

±0.25

%FS,BFSL

Repeatability

±0.05

±0.075

%FS

Hysteresis

±0.05

±0.075

%FS

Zero output

±1

±2

mV DC

FS output**

70

mV DC

Zero thermal error

±0.75

±1.0

%FS, @25℃

FS thermal error

±0.75

±1.0

%FS, @25℃

Compensated temp. range

0~50

Working temp. range

-40~125

Storage temp. range

-40~125

Stability

±0.2

±0.3

%FS/year

*Testing at basic condition,G: Gauge; A: Absolute; S: Sealed gauge

** 0BG, FS output ≥45mV

0AG, FS output ≥60mV

02A, 03A, 02GY, 03GY, FS output ≥45mV
07A, 08A, 07GY, 08GY, FS output ≥60mV


Outline Construction:


For option 0 or null, suggested installation dimension is Φ 19 +0.05/+0.02mm.




Electric Connection:



Note: The actual electric connection method, please check the parameter label enclosed with products.

Order Guide

MPM280(TH/TS/HHTi)*

Piezoresistive OEM Pressure Sensor

 

 

Range code

Pressure range

Ref.

Range code

Pressure range

Ref.

0B

0kPa~20kPa

G

12

0MPa~2MPa

G.A

0A

0kPa~35kPa

G.A

13

0MPa~3.5MPa

G.S.A

02

0kPa~70kPa

G.A

14

0MPa~7MPa

S.A

03

0kPa~100kPa

G.A

15

0MPa~10MPa

S.A

07

0kPa~200kPa

G.A

17

0MPa~20MPa

S.A

08

0kPa~350kPa

G.A

18

0MPa~35MPa

S.A

09

0kPa~700kPa

G.A

19

0MPa~70MPa

S.A

10

0kPa~1000kPa

G.A

20

0MPa~100MPa

S.A

 

 

Code

Pressure type

G

Gauge

A

Absolute

S

Sealed gauge

 

 

Code

Pressure connection

Installation

0 or null

O-ring

H1

M24×1 male

(assembled, P≤2MPa)

C1~C11 are available for pressure connections for both assembled and welded type

H2

M27×2 male

(assembled, P≤70MPa)

H3

M24×1 male

(welded, P≤2MPa)

H4

M27×2 male

(welded, P≤35MPa)

C1

M20×1.5 male,

face type seal

Pressure connection options for assembled or welded type

C2

G1/4 male

C3

G1/2 male

C4

G1/4 female

C5

M20X1.5male

waterline seal

C6

1/4NPT male

C7

1/4NPT female

C8

1/2NPT male

C9

1/2NPTfemale

C10

R1/4 male

C11

R1/2 male

PC1

Flush diaphragm

M20×1.5 male,

Top: M24×1 female

PC2

Flush diaphragm

R1/2 male,

PC3

Flush diaphragm

G1/2 male,

PD1

DN25 clamp

 

 

Code

Compensation

L

Laser trimming

M

Outer compensated resistor

(providing resistor value)

 

 

 

 

 

 

 

Code

Electric connection

1

Kovar pin(default)

2**

100mm silicon rubber flexible wires

 

 

Code

Special measurement

Y

Gauge sensor to measure vacuum(0kPa~-100kPa)

 

 

    MPM280 09 G 0 L 1 Y The whole spec

* For sensor with tantalum diaphragm and hastelloy housing, the model shall be MPM280TH, For sensor with tantalum diaphragm and 316L housing, the model shall be MPM280TS, for all Hastelloy C material sensor (Hastelloy C diaphragm and Hastelloy C housing), the model shall be MPM280HH ,for all titanium material sensor (titanium diaphragm and titanium housing), the model shall be MPM280Ti.

**For assembled and welded type, please choose the top connection and pressure connection at the same time, eg. H1C2. For other customized options not shown in the order guide, please contact us.

***For the sensor with "flexible silicone wire", the electric connection on the parameter label shall be default code "1", wire length shall be made clear on the contract.


Notes

1.We suggest you to use Floating construction when you install the sensor to prevent affecting sensor stability;

2.Please pay attention to protect sensor isolated diaphragm and ceramic compensated board, to avoid damaging sensor or affecting the performance;

3.Temperature resistant range of standard Viton O-ring of sensor is -20℃ ~ 250℃. When working temperature is lower than -20℃, or sensor is applied in critical environment, please contact us.